SDP-CC160 Temperature-Compensated Ceramic Pressure Cell
The SDP-CC160 is a compact, flat-diaphragm ceramic pressure cell designed for OEM pressure sensors and transmitters. Its alumina ceramic substrate features a screen-printed, high-temperature-fired sensing bridge, with laser-trimmed zero and full-scale output for consistent performance.
Integrated temperature compensation reduces thermal zero drift from −20 to +85°C. With an 18 mm diameter, gauge and absolute pressure options, and nominal ranges from 5 to 100 bar, the SDP-CC160 offers flexible integration for measuring air, water, oil and compatible refrigerants.
Features
• Durable Ceramic Diaphragm — Corrosion- and wear-resistant alumina ceramic for compatible media.
• Temperature-Compensated Performance — Laser-trimmed bridge with reduced thermal zero drift.
• Compact OEM Integration — Ø18 mm format with millivolt output for integration with signal-conditioning electronics.
Product Overview
The SDP-CC160 is a flat-diaphragm ceramic pressure cell with an integrated sensing bridge and temperature compensation, designed for OEM pressure sensors and transmitters.
The alumina ceramic substrate is screen printed, fired at high temperature and laser trimmed to adjust zero and full-scale output. The compensated bridge reduces thermal zero drift over −20 to +85 °C.
Available in gauge and absolute pressure versions, the compact Ø18 mm cell supports pressure measurement of air, water, oil, refrigerants and other compatible media. Nominal full-scale ratings range from 5 to 100 bar.
Product Features
- Laser-trimmed zero and full-scale output
- Integrated temperature compensation from −20 to +85 °C
- Corrosion- and wear-resistant alumina ceramic
- Flat diaphragm and compact Ø18 mm construction
- Gauge and absolute pressure versions
- Nominal full-scale ratings: 5, 10, 16, 20, 25, 30, 50 and 100 bar
- Millivolt bridge output for integration with signal-conditioning electronics
Applications
- OEM pressure sensors and transmitters
- Water pumps and compatible fluid systems
- Air compressors and pneumatic equipment
- HVAC and refrigeration systems using compatible media
- Industrial pressure monitoring and control
Application suitability depends on the selected pressure range, temperature conditions and compatibility of the process medium with the cell and seals.
Structural Characteristics
| Sensing Structure | Flat ceramic diaphragm with integrated bridge |
|---|---|
| Substrate Material | Alumina ceramic |
| Bridge Manufacturing | Screen printing and high-temperature firing |
| Output Adjustment | Laser-trimmed zero and full-scale output |
| Nominal Diameter | Ø18 mm |
| Integration | Pressure cell for installation in an OEM housing |
Environmental Conditions
| Operating Temperature | −40 to +150 °C |
|---|---|
| Storage Temperature | −40 to +150 °C |
| Compensated Temperature Range | −20 to +85 °C |
| Media | Air, water, oil, refrigerants and other compatible media |
The operating temperature range is distinct from the compensated range. Confirm compatibility with the specific medium and sealing materials.
Electrical Characteristics
| Supply Voltage | 2–30 V DC |
|---|---|
| Output | Differential millivolt bridge signal |
| Bridge Resistance | 10 kΩ ±30% |
| Full-Scale Sensitivity | 2.0–5.0 mV/V; typical 3.0 mV/V |
| Zero Offset | 0 ±0.4 mV/V |
| Resistance Temperature Coefficient | ≤100 ppm/°C (−40 to +125 °C) |
External signal-conditioning electronics are required for standard transmitter outputs such as 4–20 mA or 0–10 V.
Technical Specifications
| Product Model | SDP-CC160 |
|---|---|
| Nominal Full-Scale Ratings | 5, 10, 16, 20, 25, 30, 50 and 100 bar |
| Pressure Reference | Gauge / absolute |
| Thermal Zero Drift | ≤0.02% FS/°C (−20 to +85 °C) |
| Response Time | <2 ms |
| Overload Pressure | >2 × FS |
| Burst Pressure | >5 × FS |
| Pressure Cycles | >5 million cycles (2–5 Hz, 0–FS–0) |
| Overall Accuracy | Confirm the specification for the selected version |
FS denotes the selected full-scale pressure rating. Thermal zero drift is not an overall accuracy specification. Overload and burst ratings are not continuous operating ratings.
Dimensions
Reference dimensions for the illustrated version are listed below. Refer to the confirmed dimensional drawing for tolerances and installation requirements.
| Outside Diameter | Ø18 mm |
|---|---|
| Overall Height | 6.35 mm for the illustrated version; confirm for the selected configuration |
| Dimension Units | mm |
Confirm cell height, sealing geometry and terminal arrangement before finalizing the housing or assembly tooling.
Electrical Connection
Refer to the confirmed wiring diagram for excitation polarity, bridge output connections and terminal positions.
Connect the bridge output to suitable signal-conditioning electronics. Confirm the terminal assignment for the supplied version before applying power.
Product Selection
Select the required full-scale pressure, pressure reference and mechanical configuration according to your application. Please provide the following information when requesting samples or a quotation.
| Product Model | SDP-CC160 |
|---|---|
| Full-Scale Pressure | 5 / 10 / 16 / 20 / 25 / 30 / 50 / 100 bar |
| Pressure Reference | Gauge or absolute; confirm availability for the selected range |
| Process Medium | Fluid or gas type; specify the exact refrigerant where applicable |
| Temperature Conditions | Required medium and ambient temperature ranges |
| Electrical Requirements | Supply voltage, signal-conditioning arrangement and target system output |
| Mechanical Requirements | Cell height, sealing arrangement and installation dimensions |
| Supply Requirements | Pressure cell only, or matching electronics and semi-finished assembly support |
| Quantity | Sample quantity and estimated production demand |
Contact SensorDyna for configuration confirmation and support with pressure cells, signal-conditioning electronics and semi-finished assembly requirements.