SDP-MH7300 Hydrogen Pressure Transmitter

The SDP-MH7300 is a compact pressure transmitter designed for hydrogen pressure monitoring. Featuring 316L stainless steel construction and an integral sensing structure without an oil-filled cavity or welded isolation diaphragm, it supports demanding hydrogen measurement applications.

With typical accuracy of ±0.25% F.S. BFSL at 25°C, multiple pressure connection options and a choice of outputs, the SDP-MH7300 supports integration into PEM fuel cell systems, hydrogen storage and refuelling equipment, hydrogen-powered vehicles and test benches.

Features

• Designed for Hydrogen — 316L stainless steel construction for hydrogen pressure measurement.

• Oil-Free Sensing Structure — Integral design without an oil-filled cavity or welded isolation diaphragm.

• Flexible OEM Integration — Compact construction with multiple pressure connection and output options.

 

WhatsApp +86 15392489663
Email cary@sensordyna.com
01

Product Overview

The SDP-MH7300 Hydrogen Pressure Transmitter is designed for hydrogen pressure monitoring. Its compact 316L stainless steel construction incorporates an integral sensing structure without an oil-filled cavity or welded isolation diaphragm.

Pressure connection and output options support integration into hydrogen equipment and OEM systems.

02

Product Features

  • Designed for hydrogen measurement
  • Oil-free sensing structure
  • Compact, rugged construction
  • Multiple connection and output choices
03

Applications

  • PEM fuel cell systems
  • Hydrogen storage and refuelling equipment
  • Hydrogen-powered vehicles
  • Backup power systems
  • Test benches
04

Technical Specifications

Parameter Specification
Model SDP-MH7300
Accuracy at 25°C Typical: ±0.25% F.S. BFSL; maximum: ±0.3% F.S. BFSL
Long-term stability ±0.25% F.S./year
Pressure cycle life 10 million cycles, 0–full scale
Diaphragm material 316L stainless steel
Operating / storage temperature −40°C to +125°C; cable limited to +105°C
Insulation resistance ≥100 MΩ at 500 VDC, signal to housing
Response time Voltage: <2 ms; current: <3 ms (10–90%, without damping)

F.S. = Full Scale. BFSL = Best Fit Straight Line. Typical values are not maximum error limits.

05

Application & Installation Requirements

Select the configuration according to hydrogen service conditions, including working pressure, pressure cycling, temperature and the required sealing arrangement. Confirm the suitability of all wetted materials and seals for the intended application.

Use the dimensional drawing and wiring diagram supplied for the selected version. Any required hazardous-area approval must be confirmed for the exact configuration before ordering.

06

Product Selection

Please provide the following information for configuration review and quotation:

Selection Item Information Required
Application Equipment type, hydrogen composition and service conditions
Pressure requirements Measurement range, pressure reference, maximum operating pressure and transient peaks
Temperature requirements Medium temperature, ambient temperature and required accuracy across temperature
Electrical requirements Required output signal, supply voltage, connector type and cable length
Mechanical installation Process connection, sealing method and available installation space
Environmental requirements Ingress protection, vibration, shock and any required approvals
Project requirements Sample quantity, estimated annual demand and requested delivery date

Available ranges, outputs, supply requirements, pressure limits and temperature-compensated performance must be confirmed for the selected configuration.

Discuss Your Hydrogen Application with SensorDyna

Send us your operating conditions and installation requirements for configuration review, sample enquiries and project quotations.