SDP-M7300 High-Accuracy Glass Micro-Fused Pressure Transmitter

The SDP-M7300 is a high-accuracy pressure transmitter featuring glass micro-fused sensing technology and digital temperature compensation. With ±0.25% FS (BFSL) accuracy, it delivers reliable pressure measurement for industrial machinery, hydraulic and pneumatic systems, and automated test equipment.

Its compact design, rugged metal diaphragm and one-piece pressure body support demanding OEM applications. Multiple output signals, pressure connections and electrical connector options allow flexible integration into different equipment designs.

Features

• High accuracy: ±0.25% FS (BFSL)
• Digital temperature compensation from −20°C to +85°C
• Wide operating temperature range: −40°C to +125°C
• Gauge, sealed gauge and compound pressure options
• Voltage, 4–20 mA and RS485 output options
• Multiple wetted-material options for different media requirements

WhatsApp +86 15392489663
Email cary@sensordyna.com
Product Details
01

Product Overview

The SDP-M7300 Industrial Pressure Transmitter combines glass micro-fused sensing technology with digital temperature compensation for accurate pressure measurement across a wide temperature range. Its compact construction and one-piece pressure cavity support integration into industrial equipment and OEM systems.

Multiple output options, pressure references and wetted materials allow configuration for different measurement requirements.

02

Product Features

  • Glass micro-fused sensing technology with digital temperature compensation
  • Accuracy: ±0.25% FS BFSL
  • Compensated temperature range: −20 to +85°C
  • One-piece pressure cavity to minimize potential leak paths
  • Voltage, 4–20 mA and RS485 output options
  • Gauge, sealed gauge and compound pressure configurations
03

Applications

  • Hydraulic and pneumatic systems
  • Industrial machinery and pressure control
  • Automotive test benches and automated testing
  • HVAC and refrigeration systems
  • Data center liquid cooling systems
  • High-precision pressure monitoring
04

Structural Characteristics

Sensing Technology Glass micro-fused
Compensation Digital temperature compensation
Pressure Cavity One-piece construction
Wetted Material Options 17-4PH stainless steel; 316L stainless steel; alloys C276, 625 or 718
05

Environmental Conditions

Compensated Temperature −20 to +85°C
Operating Temperature −40 to +125°C
Storage Temperature −40 to +125°C
Shock 50 g, 11 ms
Vibration ±20 g

Confirm the temperature limits of the selected cable, connector and seals for your application.

06

Electrical Characteristics

Voltage Outputs 0.5–4.5 V; 1–5 V; 0–5 V; 0–10 V; 1–6 V
Current Output 4–20 mA
Digital Interface RS485
Insulation Resistance 100 MΩ at 250 VDC, signal-to-case
Voltage Output Load RL > 100 kΩ
Current Output Load RL < (Vsupply − 9 V) / 0.02 A
Current Consumption <10 mA*
Response Time <2 ms for voltage output; <3 ms for current output (10–90%, without damping)

Supply voltage and wiring depend on the selected output. *Confirm current consumption for the chosen version; this value does not describe the 4–20 mA loop current. Confirm the RS485 protocol and communication settings before ordering.

07

Technical Specifications

Pressure Ranges From 0–3.5 bar to 0–700 bar
Pressure Reference Gauge / Sealed gauge / Compound
Accuracy ±0.25% FS BFSL
Zero Offset ±0.25% FS
Full-Scale Offset ±0.25% FS
Total Error Band ±0.5% FS typical; ±0.75% FS maximum over the compensated temperature range
Long-Term Stability ±0.25% FS/year
Pressure Cycle Life 1 × 107 cycles, 0–FS
Overload Pressure 2 × rated pressure, capped at 20,000 psi*
Burst Pressure 3 × rated pressure, capped at 20,000 psi*

FS: full scale. BFSL: best-fit straight line. *Overload and burst ratings are subject to the selected range and construction. Confirm available range/reference combinations before ordering.

08

Dimensions

Overall dimensions depend on the pressure connection and electrical connector. Contact SensorDyna for the dimensional drawing matching your selected SDP-M7300 configuration.

09

Electrical Connection

Use the wiring diagram supplied for the selected output and connector. Confirm supply voltage, polarity and terminal assignments before installation. For RS485 versions, also confirm the A/B terminal definitions and communication settings.

10

Product Selection

Model SDP-M7300
Pressure Requirement Specify range, pressure reference and expected pressure peaks
Electrical Requirement Specify output, supply voltage and connector or cable
Mechanical Requirement Specify pressure port, wetted material and installation space
Operating Conditions Specify medium, temperature, vibration and ingress protection requirements

Contact SensorDyna for configuration matching, sample availability and OEM customization.